Abstract:
An elevated level of radon (above 1000 Bq/m3) and more than 5 % of
carbon-dioxide were discovered in indoor air in two houses in a North East
Hungarian village in 1992. The problem in these dwellings was more or less
solved when the village decided to build a sewage system. It was clear
for the authors that the two gases would flow along the drain-pipes downwards
to the area where there were no radon or carbon-dioxide before. Our data
show that the radon could be used as a tracer gas to follow the motion
of the carbon-dioxide. Based on the values measured by us the local authorities
were convinced about the necessity of a mitigation action. The success
of mitigation was checked by measurements.